<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-14 02-44-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 44 dBuV YLEX
Pilot RDS Phase Difference
7.7 kHz 2.7 kHz 55 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 63 kHz 19040 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-0,9 dBr 0,03 dBr 0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" YLEX " 6202 10 (Pop M) 0 1 1 1 2:44, 14.01.2026
RT
-
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6207, 6205, 6201, 6203
FM Scope Max at: 63 kHz MIN: 13 kHz % above 76 kHz: 0,0053 Acquired: 2026/01/14 2.43.25 Total samples: 19040 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 0,6 dBr MIN: -0,9 dBr AVE: 0,03 dBr % above 12,2 dBr: 0,0 Last value: -0,1 dBr (2026/01/14 2.43.24) 02.30 02.32 02.34 02.36 02.38 02.40 02.42 -1.0 -0.5 0.0 0.5 1.0 Pm [dBr]